White Swan Building 2200 N. Lamar Street
Dallas, TX 75202
(214) 978–BLUE
Hours of Operation Wednesday – Thursday: 11:00 a.m. – 10:00 p.m. Friday – Saturday: 11:00 a.m. – 1:00 a.m. Sunday: 11:00 a.m. – 10:00 p.m. Monday – Tuesday: Open for concert nights
|
|
 |
|
House of Blues offers full in-house production capabilities, post-production facilities and a distribution platform. We also have the ability to capture any live event in different media formats and deliver a finished product, either live or on recorded media, to your specification.
|
 |
|
|
|

|
 |
|
General production information for House of Blues Dallas
|
- House of Blues consists of a 1,625 person capacity two story music venue, a dedicated restaurant, retail store and future Foundation Room located in downtown Dallas.
- First floor of the music hall is typically GA and the second floor is fixed seating.
- There is a no flash photography policy.
- No Pyrotechnics are allowed.
- All video taping requests must be advanced with House of Blues at least three days in advance. A release or contract must be signed for any video taping. Any video production greater than a consumer camcorder must be cleared in advance through Tommy DeBeaudry, Production Manager.
- All photographers and members of the press must obtain clearance from our Publicity Department (Alli Brodine).
- All guest-lists are due by 5 p.m. the day of the show.
- House of Blues requires that current Stage and Lighting Plots, Input Lists, Backline and Hospitality Riders be provided directly to the Production Office
|
|
|
 |
|

|
 |
|
Load-in and parking information for House of Blues Dallas
|
|
Load-in: |
Cars, vans, bob-tail trucks, semi's and buses w/trailers load-in to be advanced with Production prior to show.
Venue has dedicated dock for 1 truck or bus, plus parking next to the venue for 1 bus or bob-tail. |
|
Parking: |
Advanced with production prior to show. |
|
|
 |
|

|
 |
|
Dressing room information for House of Blues Dallas
|
| Green Room #1: |
Private restroom w/shower on stage level stage right |
| Green Room #2: |
Private restroom w/shower on first floor stage left |
| Green Room #3: |
Wardrobe room and catering on second floor stage left |
|
|
 |
|

|
 |
|
Electrical information for House of Blues Dallas
|
|
Guest Audio: |
100a 3 phase Cam Lock located Stage Left at Stage Level |
|
Guest Lighting: |
200a 3 phase bare tails tie in located Stage Right at Stage Level |
|
Guest Stage Power: |
100a 3 phase Cam Lock located US Center at Stage Level plus 24 -20a 110v Circuits located SL, SR and US |
|
|
 |
|

|
 |
|
Front of house information for House of Blues Dallas
|
|
FOH Console: |
MIDAS Heritage 2000 48/4/8 Stereo Modules |
|
FOH EQ: |
KT DN 9340 and DBX 160sl Blue |
|
Main Drive: |
EV Net Max Speaker Management System |
|
FOH Processing: |
(1) TC Electronics D Two
(2) Yamaha SPX 2000
(1) Lexicon PCM 91
(1) Harmonizer Eclipse |
|
FOH Gates/Comps: |
(2) Klark Teknik DN 514 Quad Gates
(2) dbx 162 SL Purple - 4 channel comps
(2) Klark Teknik DN 500 Stereo Comps
(2) Klark Teknik DN 504 Quad Comps |
|
Playback/Record: |
Tascam CD A700 CD/Cassette Combo |
|
Main Speakers: |
(16) EV XLC 127+ Flown Line Array (8 per side)
(6) EV XLC 118 Flown Line Array Subs (2 per side) |
|
Main Subs: |
(3) EV Quad 18" X Subs (left, right and center) |
|
Main Amps: |
EV P3000
EV P1200 |
|
Sub Amps: |
EV P3000 |
Downstairs Under Balcony Delay Speakers: |
(4) EV Xi / 1082 |
|
|
 |
|

|
 |
|
Monitor information for House of Blues Dallas
|
|
Console: |
Midas Heritage 3000 48/4/TP |
|
Wedges: |
(14) EV XW12 Monitors
(4) EV XW15 Monitors |
|
Fill - Drums: |
(2) EV XW15
(2) DB Sound S118 EVX80 NFE |
|
Fill - Sides: |
(2) EV Xi 1183
(2) DB Sound S118 HPL42 NFE |
|
Monitor Drive: |
DMX 4800
EV DX38 |
|
Amps: |
EV CP3000
EV CP1200 |
|
Intercom: |
2 channel, 6 station Telex (Lights and Sound) |
|
|
 |
|

|
 |
|
Mics and digital inputs information for House of Blues Dallas
|
|
Microphones: |
Sennheiser -
(4) 421
(3) 614
(4) 865
(2) 901
(2) 902
(8) 904
(2) 905
(5) 906
(4) 914
(6) 935
(7) 945
Other -
(2) Audio Technica ATM 23 HE
(2) Audio Technica ATM 871 R
(2) AKG SE 300B
(2) AKG C 3000B
(2) AKG C 93 Capsules
(2) AKG C418
(2) AKG D112
(4) Beta 57
(1) Beta 91
(4) Beta 98
(9) SM 57
(7) SM 58
(2) SM 7
(3) SM 81
(2) KSM 44 |
|
DI Boxes: |
(2) Countryman Active DI DT85
(4) Passive DIDirector |
|
Mic Stands: |
Full compliment |
|
Mic Lines: |
Full Compliment |
|
|
 |
|

|
 |
|
Lighting information for House of Blues Dallas
|
|
Lighting Plot: |
The lighting plot is included as part of the downloadable production specs. See the top of this page. |
|
Dance Floor Position: |
Pipe around Dance Floor above 1st Floor - fixed |
|
FOH Fixtures: |
(2) Source 4 Lekos with 26 degrees
(2) Martin Mac 700 Wash Fixtures |
|
FOH Position: |
Straight Truss above 2nd Floor on Motors |
|
Follow Spots: |
(2) Lycian 400 HTI |
|
Lighting Console: |
Avolites Pearl 2008 |
|
Dimmers: |
(24) 2.4kw Avolites Art 2000 Dimmer Rack
(6) Open 2.4k dimmers - per advance |
|
Stage: |
(3) 32' 20" x 20" Cross Stage Trusses on two - 1 Ton Motors
(1) 32' 12" x 12" Cross Stage Truss for Scenic Upstage
(3) 6 Bars Par 64 - 1k NSP on Up Stage Truss
(4) 4 Bars Par 64 - ACL on Up Stage Truss
(2) ETC Source 64 - 19 Degree Lekos on Upstage Truss
(3) 6 Bars Par 64 - 1k NSP on Mid Stage Truss
(4) 4 Bars Par 64 - ACL on Mid Stage Truss
(2) Audience Blinders on Downstage Truss
(4) 4 Bars Par 64 - 1k MFL on Downstage Truss
(4) 19 Degree Lekos on Downstage Truss |
|
Stage Motors: |
(6) 1 ton CM chain hoists on Lighting Truss
(3) 1/2 ton CM chain hoists on Scenic Truss |
|
Stage Technology: |
(4) Martin Mac 700 Spots on Up Stage Truss
(2) Martin Mac 700 Wash on Up Stage Truss
(4) Martin Mac 700 Spots on Mid Stage Truss
(4) Martin Mac 700 Wash on Mid Stage Truss
(2) Martin Atomic 3000 Strobes on Mid Stage Truss
(2) Martin Atomic 3000 Strobes on Up Stage Truss
(2) DF-50 Hazers |
|
|
 |
|

|
 |
|
Stage details for House of Blues Dallas
|
|
Dimensions: |
30'W x 25'D wood finish |
|
Height: |
4' 6" |
|
Proscenium Opening: |
30'W x 20'H |
|
Stage Left Wing: |
20'D x 10'W |
|
Stage Right Wing: |
20'D x 10'W |
|
Case Storage: |
Side Stage |
|
Stage Description: |
Low-gloss finish hard wood deck |
|
Risers: |
Full compliment
(10) 4' x 8' Decks with legs (24", 16", 12") |
|
Deck to Lighting Truss: |
20' |
|
|
 |
|

|
 |
|
Softgoods information about House of Blues Dallas
|
|
Main Curtain: |
30'W x 25'H bi-parting electric draw located Down Stage Right and Stage Left |
|
Curtain 1: |
30'W x 20'H black duve. bi-parting curtain, Upstage Scenic Truss |
|
Wing Curtains: |
20'W x 20'H black duve bi-parting curtains SL and SR wall |
|
Curtain 4: |
30'W x 20'H burgundy swag, Upstage Scenic Truss |
|
HOB Logo: |
Upstage Scenic Truss |
|
|
 |
|

|
 |
|
Backline equipment information for House of Blues Dallas
|
|
*Backline availability per advance with Production Manager |
|
Bass: |
Ampeg SVT4 Pro Head |
|
Bass: |
Ampeg 810E Cabinet |
|
Guitar: |
Fender Twin Reverb ('65 reissue Blackface model) |
|
Guitar: |
Roland JC120 2x12 |
|
Guitar: |
Marshall JCM2000, 100watt w/4x12 slant 1960A |
|
Drums: |
DW - Drums
Kicks - 20" x 18", 22" x 18"
Toms - 8", 10", 12", 13", 14", 15", 16", 18"
Snares - 14" x 5.5" maple
Full Compliment of Stands, Thrones, Pedals
* snare drums are for back-up, please bring your own.
Zildjian - Cymbals
Sabian - Cymbals |
|
Percussion: |
Quinto (10 3/4")
Conga (11 1/2")
Tumba (12 1/4")
Bongos 7" & 8 1/2"
Timbales 14" & 15" |
|
Keyboards: |
Yamaha - S 90 Keyboard
Hamond B3 with Leslie with bench and pedal |
|
DJ Rig: |
* Portable dj rig in coffin. Bring your own needles and mats.
Groove Masters ii Pro MP4
(2) Technics SL 1200 MK5 Turntables
(1) Pioneer DJM600 Pro
(1) Denon DND9000 |
|
|
 |

|
 |
|

|
 |
|
General production information for the Cambridge Room
|
- This is our 400 capacity GA music room / special event room located directly off the main lobby of the Music Hall. It offers great ambiance, a large bar and a great PA.
- Dressing rooms may be available depending on Music Hall concert schedule.
- Venue provides one qualified sound engineer to do FOH and Monitors that loads in and out.
- Venue provides one qualified Lighting Director that loads in and out.
- Venue provides one Stage Manager/loader.
- Case storage is very limited.
- Band Must Advance Show With Production Coordinator and Verify Times.
- 10 guests per band - please provide that list by 5p.m. on the day of the show.
- Parking is very limited and has to be pre-arranged prior to load in.
|
|
|
 |
|

|
 |
|
Stage details for the Cambridge Room
|
|
Dimensions: |
16' x 16' at 2' |
|
|
 |
|

|
 |
|
Wings information for the Cambridge Room
|
|
Dimensions: |
8' x 4' Stage Left and Right |
|
|
 |
|

|
 |
|
Front of house information for the Cambridge Room
|
|
Console: |
(1) Yamaha M7CL Digital mixing console |
|
Speakers: |
(2) EV Plasma P1 15" powered 2 way Transducer and 3" compression driver diaphragm per side |
|
Subs: |
(2) EV Plasma P2 Single 18" powered speakers per side |
|
|
 |
|

|
 |
|
Monitors information for the Cambridge Room
|
|
Monitors and FOH are both done from the same console |
|
Speakers: |
(6) EV SxA250 15" two way powered floor monitors |
|
|
 |
|

|
 |
|
Power information for the Cambridge Room
|
|
Monitors and FOH are both done from the same console |
|
Speakers: |
(6) EV SxA250 15" two way powered floor monitors |
|
|
 |
|

|
 |
|
Video information for the Cambridge Room
|
|
Stage Power: |
(5) 20a Edison outlets behind the stage |
|
|